Bolt RangeBolts with limited installation space or with hexagonal holes Installation on threaded end: M30 and above Installation on hexagonal head: M20 and above Total length of bolts: 150-6000mm
Preload Accuracy1.5%
Temperature Range-40~85℃
Temperature Accuracy±1℃
Explosion ProtectionEX ia IIC T4 Ga
Ingress ProtectionIP67
Battery Life10 years
Product Overview
Technical Specifications
Downloads
System Architecture
Overview
The SAS series wireless bolt preload sensors are industrial-grade sensors designed to monitor the health of critical bolts in industrial equipment. Built for harsh environments, these sensors offer exceptional resistance to interference, high accuracy, ultra-low power consumption, and long-lasting durability for continuous operation.
Using ultrasonic technology, each sensor accurately measures the time of reflective ultrasonic waves. Additionally, the integrated temperature probe measures the surface temperature of the bolt. With a temperature compensation algorithm, the sensor ensures precise and reliable measurement of the bolt's preload (axial tensile force) across varying temperatures.
The SAS120 features a slim probe design, making it perfect for applications with limited space, such as blade bolts in wind turbines, or bolts with internal hexagonal holes.
The sensor is transmitted wirelessly to a remote monitoring system, enabling users to remotely monitor the bolt preload and receive timely alerts in case of loosening, fatigue, or fracture. This continuous monitoring ensures safe operation, reduces unplanned downtime, and minimizes maintenance costs.
The SAS series bolt preload sensor is installed non-intrusively at one end of the bolt. It emits ultrasonic waves into the bolt's interior, and when these waves reach the opposite end or a fracture surface, they are reflected back to the sensor for processing. Using advanced signal processing technology and temperature compensation algorithms, the sensor accurately calculates the preload and evaluates the bolt’s condition, detecting issues such as loosening, fatigue, or fracture.
Form FactorUltra-thin probe design; separate main body and probe
Bolt RangeBolts with limited installation space or with hexagonal holes Installation on threaded end: M30 and above Installation on hexagonal head: M20 and above Total length of bolts: 150-6000mm
Preload Accuracy1.5%
Temperature Range-40~85℃
Temperature Accuracy±1℃
Data Acquisition Period1/2/5/10/15/20/30/60/120/240/360/480/720/1440 minutes
Communication2.4GHz Wireless Sensor Network (Bluetooth 5.0), line-of-sight range 300m
Battery4000mAh Li/SOCL2; replaceable
Dimensions95mm x 47mm x 37mm (main L x W x H)
Weight70g
Operating Temperature-40~85°C
Operating Humidity10%~90% RH
EnclosureMetal and polyamide with fiberglass
Explosion ProtectionEX ia IIC T4 Ga
Ingress ProtectionIP67
MountingProbe: Industrial-grade epoxy, optional auxiliary fastening structure Main unit: Bracket